Product information

This product supersedes product no: L52568

Step 1)

Remove surface rust, scale, paint by mechanical means, spray cleaner to degrease the inspection area. Leave to dry.

Step 2) Spray penetrant over the area and allow to soak for about ten minutes.

Step 3) Remove all excess penetrant using a dry cloth and wipe dry.

Step 4) Spray developer evenly over the inspection area and wait a few minutes until the area dries white. Any surface defects will appear in red contrast.

SDS