Features

  • Protects all common metals in cooling systems from corrosive attack
  • Protects against cavitation erosion
  • Compatible with glycols for frost protection.
  • Safe to apply and handle

Benefits

  • Approved by major diesel engine manufacturers
  • Simple control test

Specification

Safety Data Sheet (SDS)

Documents

Directions for use

NALFLEETâ„¢ 2000 has been designed for use in all common types of engine cooling water systems. NALFLEETâ„¢ 2000 will protect ferrous metals, copper and copper alloys and all other metals including aluminium components. NALFLEETâ„¢ 2000 will not affect rubber gaskets or other non-metallic components within the cooling system.

For general guidance where aluminium is present:

No aluminium present - Use Engine Water Treatment 9-108 or Rocor NB Liquid

With Aluminium - Use NALFLEET 2000 or Cooltreat AL

Sampling and Testing
The WSS Motor Ship Test Kit (777066) provides the necessary equipment to carry out the control tests. Obtain a representative sample of the cooling water. Carry out the tests immediately after sampling (following the instructions given in the Test Kit) and log the results in Waterproof. The results should be sent to WSS as stated in the Waterproof instructions. It is important that testing is carried out at least once per week, to ensure levels of treatment are correct.

Dosing and Control
Engine cooling systems should be drained, flushed and if necessary, chemically cleaned, to remove old rust and scale deposits before treatment with NALFLEETâ„¢ 2000 can begin.

NALFLEETâ„¢ 2000 is easy to apply as received, and is fully compatible with water in ethylene glycol solutions. It contains an anti-scalant which helps to keep engine systems clean and free from corrosion and scale formation. NALFLEETâ„¢ 2000 maintains design heat transfer efficiencies and extends the life of the engine.

Cases of unusual coolant loss should be checked and remedial action taken. NALFLEETâ„¢ 2000 should be introduced during circulation of the cooling water. NALFLEETâ„¢ 2000 is best added by means of a feeder installed on a by-pass to the circulating system or in smaller systems, it can be added directly to the header tank.

Initial treatment is at a rate of 32 liters of NALFLEETâ„¢ 2000 per 1m3 of coolant to give a control level of 700 to 1,500ppm as nitrite (1,000 to 2,250ppm as sodium nitrite), pH 8.3 to 10.0. Recommended Nitrite residual 840 ppm Nitrite ( 1,260 ppm as Sodium Nitrite) for routine maintenance.

Overdosing with NALFLEETâ„¢ 2000 is not harmful to the system. Control by a simple test for nitrite and pH. Refer to table below for guide to dosing.

Nitrite ppm

0

250

500

750

1000

1500

Sodium Nitrite ppm

0

375

750

1125

1500

2250

NALFLEETâ„¢ 2000 lit/m3

32

24

16

8

0

0