1. Add the correct amount of Glo-Leak tracer fluid to the system (dosage rates as below). Glo-Leak may be added in one of the following ways:
· Directly into the compressor oil reservoir
· Via a standard oil charge pump
· Through the charging port on the compressor suction valve
2. Operate the system for enough time to allow Glo-Leak to permeate all suspected leak areas. Some leaks may show up within minutes. Others may take hours or even days to reveal themselves.
3. Scan the system to locate any leaks by shining the UV lamp supplied over all areas of possible leaks. The precise source of a leak is revealed by a fluorescent yellow or yellow-green glow.
4. Once identified, repair the leaks.
5. Clean off any excess Glo-Leak with Glo-Klenz (or with another suitable cleaner/degreaser).
Glo-Leak can now remain in the system so that regular leak checks during maintenance may be performed with ease. This should be done at regular intervals to ensure optimum performance.