The Turbo nozzles meet the German standard DIN 14367 for branchpipes. Flowrates can be selected by adjusting the sleeve and opening and closing by means of the lever. A special feature is the extinguishing power, due to optimal droplet size also at the full range of the 0 to 120 degrees adjustable watr filled spray stream. The nozzles have two pointers which help to feel the selected flow rate as well s the type of stream. With flash over position. Swivelling inlet connection also under pressure. The connection to hose coupling is 2 inch male thread.
Adjustable flowrate from 60 to 130 to 235 ltr/min
Extinguishing in the vicinity of electrical systems